            Project Introduction

            Contact resistance is the resistance of a current flowing through a closed contact point in time. This type of measurement is performed on components such as connectors, relays, and switches. The contact resistance test can understand the connection quality of the line and its conductive characteristics, to avoid dangerous overheating of the contacts.

            Contact resistance formation principle

            Observe the surface of the connector contact under the microscope. Although the gold layer is very smooth, you can still observe the convex part of 5-10 microns. It will be seen that the contact of the pair of mated contact pieces is not the contact of the entire contact surface, but the contact scattered at some points on the contact surface. The actual contact surface must be smaller than the theoretical contact surface. Depending on the smoothness of the surface and the size of the contact pressure, the gap between the two can be several thousand times.

            The actual contact surface can be divided into two parts: one is the real metal-to-metal direct contact part. That is, the contact microdots without transition resistance between metals, also known as contact spots, are formed after the interface film is destroyed by contact pressure or heat. This part accounts for about 5-10% of the actual contact area. The second is the part that contacts each other after contaminating the film through the contact interface. Because any metal has a tendency to return to the original oxide state.

            In fact, there is no truly clean metal surface in the atmosphere. Even if a very clean metal surface is exposed to the atmosphere, it will quickly form an initial oxide film of a few microns. For example, copper takes only 2-3 minutes, nickel takes about 30 minutes, and aluminum takes only 2-3 seconds to form an oxide film with a thickness of about 2 microns. Even the particularly stable precious metal gold, due to its high surface energy, will form an organic gas adsorption film on its surface. In addition, dust and the like in the atmosphere also form a deposited film on the surface of the contact. Therefore, from the microscopic analysis, any contact surface is a contaminated surface.

            Factors affecting contact resistance

            1. Contact form

            2. Contact pressure

            3. The finish of the contact surface

            4. Stability of contact resistance in long-term work

            5. Temperature

            6. Material properties

            7. Use voltage and current

            Testing requirements

            1. Test with 300V insulation resistance meter.

            2. The contact resistance of the tested product should be less than 1Q.

            3. The test product must be above 5PCS.

            Test description

            1. Qualified contact resistance test does not mean reliable contact. The test proves that it is only used to check whether the static contact resistance is qualified, and it cannot guarantee the reliable use of the contact in a dynamic environment.

            2. The contact resistance is mainly affected by factors such as contact materials and surface conditions.


            Online consultation

            Online consultation

            Recommend
            • Australian RCM certification

              Australian RCM certification

              Australian RCM certification

            • Label printer ANATEL certification

              Label printer ANATEL certification

              Label printers entering the Brazilian market, ANATEL certification is an essential passport! It is the recognition of the Brazilian Telecommunications Authority for the safety and compliance of electronic products, without which products cannot be legally sold.

            • Label printer SRRC certification

              Label printer SRRC certification

              SRRC certification is not only a guarantee of product compliance, but also a key to opening up the market.

            Contact resistance test

            Contact resistance is the resistance of a current flowing through a closed contact point in time. This type of measurement is performed on components such as connectors, relays, and switches. The contact resistance test can understand the connection quality of the line and its conductive characteristics, to avoid dangerous overheating of the contacts.

            Get a quote
            主站蜘蛛池模板: 国产19p| 桔子av一区二区三区| 激情五月开心婷婷深爱| 在线99国产| 成人午夜视频在线观看高清| 亚洲成av人片天堂网无码| 亚洲人成无码网站久久99热国产| 久久综合色_综合色88| 狠狠五月深爱婷婷网| 国产亚洲AV| 中文字幕乱码人妻无码久久| 国产白丝护士AV在线网站| 国产成人乱色伦区| 亚洲人妻中文字幕| 久久中文人妻| 丁香五月亚洲综合在线国内自拍 | 黄色电影一区二区| 成人日本有码在线| 国产成人精品无码专区| 日韩黄色av一区二区三区| 五月天丁香| 亚洲全乱码精品一区二区| 色综合天天综合网中文伊| 美女粉嫩啪啪高潮喷白浆动漫| 亚洲天堂无码| 97在线碰| 日本一区二区三本视频在线观看| 久久99久久99精品免视看国产| 国产在线不卡精品网站| 日韩av手机免费观看| 好吊色妇女免费视频免费| 国产精品呻吟一区二区三区| 国产亚洲精品中文字幕| 醴www,亚洲熟女,Com| 亚洲男人天堂| 自拍偷拍亚州精品视频| 激情综合网激情五月伊人| 国产精品美女久久久久久久久| 免费国产黄网站在线观看| 亚洲成在人线在线播放无码| 免费观看全黄做爰大片|